Learn the essential best practices for creating compliant eCTD packages based on our analysis of successful FDA, EMA, and PMDA submissions.
After analyzing over 200 successful eCTD submissions to FDA, EMA, and PMDA, we've identified the critical best practices that separate accepted submissions from rejected ones.
The electronic Common Technical Document (eCTD) is the standard format for regulatory submissions across major agencies. While the concept seems straightforward, the devil is in the details.
The Problem: Invalid XML is the #1 cause of submission rejection.
Best Practices: - Validate against the correct DTD version for each agency - Use consistent date formats (YYYY-MM-DD) - Ensure all file paths use forward slashes - Verify checksum values match actual files
Tool Recommendation: Always validate with the agency's official validator before submission.
Correct: Directory structure should follow eCTD specification with proper folder hierarchy and file naming conventions.
Common Mistakes: - Using backslashes instead of forward slashes - Including spaces in file names - Inconsistent numbering schemes - Missing required folders
The Golden Rule: Every hyperlink must work perfectly. One broken link can delay approval by months.
Best Practices: - Use relative paths, not absolute paths - Test all links in the final eCTD package - Include meaningful anchor IDs - Maintain link validity across sequences
Example: Use relative paths with proper xlink:href attributes for hyperlinks.
Too Granular: Creating separate PDFs for every tiny section (makes navigation difficult)
Too Coarse: One massive PDF for entire modules (reduces usability)
Sweet Spot: - Module 2 sections: Separate PDFs per major subsection - Module 3-5: Balance between document size (< 50MB) and logical sections
Reviewers need to navigate documents quickly. Always include: - PDF bookmarks matching document structure - Table of contents with working links - Consistent bookmark naming across documents - Depth appropriate to document length (3-4 levels max)
Key Differences: - Module 1 is US-specific - Requires comprehensive-table-of-contents.xml - Must include FDA forms (Form 356h, etc.) - Special requirements for amendments and supplements
Common Gotchas: - Sequence numbering must be correct (0000, 0001, 0002...) - Electronic signatures must follow 21 CFR Part 11 - Application type codes must match submission type
Key Differences: - Module 1 varies by EU member state - Requires eu-regional.xml - Different lifecycle management approach - RMS/CMS procedures for centralized applications
Common Gotchas: - Date formats must be DD Month YYYY (not MM/DD/YYYY) - Product naming conventions differ - Marketing authorization variations have specific requirements
Key Differences: - Module 1 is Japan-specific (with Japanese language requirements) - Specific document naming conventions - Different granularity expectations - Unique lifecycle management
Common Gotchas: - Both English and Japanese summaries may be required - Stricter validation rules - Cultural considerations in document presentation
Before submitting any eCTD, verify:
XML Files: - [ ] Validated against correct DTD - [ ] All file references are correct - [ ] Checksums match - [ ] Operation types are correct - [ ] Sequence numbering is sequential
PDF Files: - [ ] All files < 50MB (best practice) - [ ] Searchable text (OCR if needed) - [ ] Bookmarks present and hierarchical - [ ] No corrupted pages - [ ] Consistent fonts and formatting
Hyperlinks: - [ ] All links tested and working - [ ] Relative paths used - [ ] Anchor IDs match targets - [ ] No broken references
Folder Structure: - [ ] Matches eCTD specification - [ ] File names follow conventions - [ ] No extra files or folders - [ ] Consistent across sequences
Validation Tools: - FDA ESG Validator - EMA Validation Service - Lorenz Docubridge (commercial) - DossiAIr (automated eCTD generation)
Reference Materials: - ICH M8 eCTD Specification - FDA eCTD Technical Conformance Guide - EMA eCTD Implementation Guide - PMDA eCTD Guidelines
Manual eCTD creation is error-prone and time-consuming. Modern platforms like DossiAIr automate: - XML generation with zero errors - Folder structure creation - Hyperlink management - Validation against agency specifications - Sequence management across lifecycle
Result: From 8 hours of manual work to 5 minutes of automated generation.
Creating compliant eCTD packages requires attention to countless details. The best practices outlined here, learned from 200+ successful submissions, will help you avoid the most common pitfalls.
Key Takeaways: 1. Validate early and often 2. Test all hyperlinks 3. Follow agency-specific conventions 4. Use automation where possible 5. Maintain comprehensive QC checklists
---
Need help with eCTD submissions? [Contact our regulatory experts](https://dossiair.com/contact) for a free consultation.
Part of the DossiAIr team, passionate about transforming regulatory submissions through AI.
Learn more about our team →